FEATURES
Every capability here exists in the app.
The capabilities included in the current release, arranged by workflow; Mesh is marked as a future release and is not part of the current purchase.
CURRENT RELEASE
What HHOYU PRO includes today.
These capabilities match App Store release 1.1.3.
| Capability | Current release |
|---|---|
| Local import (ZIP / RAR / folder / USB / chat apps) | Available |
| MPR (oblique and thickness) | Available |
| Dental arch CPR and cross-sections | Available |
| 3D surface and internal bone structure | Available |
| 3D cutaway and ROI local window | Available |
| AI-assisted segmentation | Available |
| Implant position illustration (standard / special) | Available |
| Remote access (hospital / DICOMweb / PACS / push) | Available |
| Privacy check and compressed sharing | Available |
| Key image / 3D video export | Available |
| Angle, HU, bone density and unlimited measurements | Available |
| Mesh 3D models | Future release |
Each row is checked against the current official build and running interface; unimplemented, planned or third-party-dependent capabilities are not marked Available. Remote access still needs an address, account and network permission from the hospital or imaging provider.
Full feature detailsTHE VIEWER
Read the same scan from several dimensions.
MPR, CPR, cutaway and ROI share one localisation model, so you do not lose your place when switching.

MPR
Linked axial, coronal and sagittal planes with oblique reformatting and slab thickness, so one anatomical point can be followed in a single view.
MPR, CPR and 3D surface viewing are available in both versions; cutaway and ROI are PRO.
IMPLANT POSITION ILLUSTRATION
Show implant position in 3D, so spatial relationships are easier to explain.
Use the 3D model and cross-sections to show how an implant model sits relative to the jaw, teeth and surrounding anatomy — for case presentation and clinician-patient communication.
- 1
Standard and special implants
Switch between standard and special implants in the toolbar; the demo case shows a standard implant and a zygomatic implant (Ø4.0 × 52.5).
- 2
Adjust the model
Drag and rotate in the cross-section, fine-tune by ±1° and flip; the 3D view follows.
- 3
Distance reference
Distance to the canal and buccolingual bone width are shown for communication; parameters and limits follow the current version.
Implant position and distance are for drawing-based communication only. They do not replace professional implant planning software and must not be used to make surgical guides.


SAME CASE · 3D
Confirm the zygomatic implant in 3D.
Standard and zygomatic implants in the same case, checked against bone walls, sinus and canal.
TEACHING
Turn a case into a lesson.
Cut, rotate, pick the angle, then export key images or a 3D video; the same case can be taught again in a department meeting, a classroom or a live session.
Lesson material
Export key images and 3D video directly, without screenshots and re-alignment.
Reuse the case
The case library keeps the original data, so any view can be reopened later.
Explain at any depth
Use the same anatomy for a patient, a student or a peer.
The sample slide was made by a clinician from 3D imagery exported with HHOYU PRO.


AI-ASSISTED SEGMENTATION
Bring 3D anatomy into view, faster.
An on-device neural network segments the maxilla, mandible, dentition and mandibular canal, and colours them in the 3D view.
On-device compute
The model runs locally. Scans are not uploaded to a cloud service.
Maxilla, mandible, dentition
Use the result as a starting point for 3D review and spend less time tracing by hand.
Mandibular canal
The left and right mandibular canals are labelled separately so their path can be compared in 3D.
~10 s
AI-assisted segmentation
On supported devices and typical cases; actual time depends on device, volume size and runtime conditions.
Available in the PRO version; requires a device with sufficient memory.
AI-assisted segmentation provides anatomical reference only. It is not a diagnosis, and results must be reviewed by a clinician. Processing is typically in the order of ten seconds, but varies with device model, volume size and runtime conditions.
PRIVACY & SHARING
Run a privacy check before sharing, so case data stays under control.
A share copy, DICOM field cleanup and compression make cases easier to use for clinician-patient communication, peer discussion and teaching.
Open the case
Pick the study you want to share from the case library.
Choose the range
Select the images to include.
Privacy check
Turn on “Remove patient information” and keep only what viewing and measurement need.
Compress
Choose the original size or a compressed copy of about 100 / 50 / 20 MB.
Choose a channel
Create a ZIP, then send it through the system share sheet, AirDrop or a chat app; HHOYU does not relay it through a cloud.
Done
The shared file is a copy; the original stays untouched.

What does the privacy check actually change?
With de-identification on, HHOYU PRO rebuilds a DICOM share copy from a whitelist: the patient name becomes ANONYMOUS and the patient ID becomes a random number; birth date, study date, institution and study description are omitted; private tags and sequences (SQ) are dropped; study, series and image UIDs are regenerated.
- Keeps the geometry, grayscale mapping and pixel data needed for viewing and measurement
- The share copy is stored separately; the original case is not modified
- Does not remove text, annotations or overlays burned into the pixels
- Cannot guarantee privacy after a third-party tool processes the file again
- Once sent through AirDrop, chat apps or another system channel, transfer and retention follow that service
This is field-level de-identification, not full anonymisation, and it is not a compliance certification. Confirm the image content and the recipient before sharing externally.
Release notes
How this list is maintained
The table is checked line by line against the current app build (1.1.3) and the running interface. Capabilities that are unimplemented, planned, or dependent on third-party configuration are not marked as supported.
If a listed capability is missing in your app, check the version and device memory requirements first, then report it to support.
Current release
Local import, MPR / CPR, 3D surface and internal structure, cutaway, ROI, AI-assisted segmentation, implant illustration, remote access, privacy sharing and export.
Future release
Mesh 3D models with STL / OBJ / PLY export; not included in 1.1.3 and not part of the current purchase.
Requirements
Remote retrieval needs an address and credentials from the hospital or provider; cutaway, ROI and AI need sufficient device memory.
Make the next CBCT a conversation that lands.
Download HHOYU PRO free and take the case to your patient, your peers and your class.
iPhone · iPad · Mac · Free on the App Store